4 Parameter settings
BU 0510 EN
technische Änderungen vorbehalten
37
Parameter
Setting value / Description / Note
Device
Supervisor
Parameter
set
P630
Position slip error
SK 530E
S
0.00...99.99 rev
[ 0 ]
The permissible deviation between estimated and actual position can be set here. Once
a target position is reached, the estimated position is set to the current actual position.
If the value set is too small, the error message "E14.5 "Position change and speed do
not match" may occur in the slip errormonitoring.
The slip error monitoring is deactivated when the value set is "0".
P631
Abs/Inc slip error
SK 530E
S
0.00...99.99 rev
[ 0 ]
The permissible deviation/slip error between absolute encoder and incremental encoder
can be set here.
If the value set is too small, the error message "E14.6 "Position change absolute and
incremental encoder do not match" may occur in the slip error monitoring.
The monitoring is deactivated when the value set is "0".
P640
Unit of pos. value
SK 530E
S
0 ... 9
[ 0 ]
Setting the units of measurement:
0:
Rev (revolution)
1:
° (degree)
2:
rad (radiant)
3:
mm (millimetre)
4:
cm (centimetre)
5:
dm (decimetre)
6:
m (metre)
7:
in (inch)
8:
ft (feet)
9:
(no
unit)
NOTE: