Genovation, Inc.
40
MiniTermPro
NOTE: It is generally not recommended to mix the Genovation command set with
the FEh compatibility mode since the device switches over to compatibility mode
on detection of the FEh. To get back to the Genovation command set, issue one
of the @ commands. To show an @ on the LCD and stay in compatibility mode,
send value 0xA0 (decimal 160).
For more information regarding the HD44780 LCD command set consult the data
sheet for any HD44780 compatible LCD.
For more information on LCD Smartie visit:
http://lcdsmartie.sourceforge.net/
For
more
information
regarding
the
MiniTerm-as-Serial-LCD,
consult
www.genovation.com for application notes we have on this subject.
‘b’ – 62h – LCD Backlight Brightness (v6.00 and later)
The LCD brightness can be adjusted on MiniTerms v6 and newer. The range of
values is 0 (off) to 9 (maximum). Reducing the brightness will prolong battery life
in units that are battery powered.
Example: Set brightness to a middle value.
Prefix Command Type
Param
ASCII:
@
b
^E
Dec:
64
98
5
Hex:
40h
62h
05h
You may also use ASCII values 0x30 (‘0’) to 0x39 (‘9’) for the parameter.