GE-BIN4 INSTALLATION
Section B-16
GE-BIN4
Specifications
Master Control
Storage temperature
-4°F to 131°F (-20°C to 55°C)
Operating temperature
32°F to 122°F (0°C to 50°C)
Humidity
90% maximum Non-condensing
Weight
3.52 lb (1.6 kg)
Size
12 1/4” x 11” x 4 3/4” (32 cm x 28.8 cm x 11.5 cm)
Protection index
IP 66
Warranty
2 years
POWER SUPPLY
Operational voltage range (SW1 on 115 V)
92 to 125 V
Operational voltage range (SW1 on 230 V)
184 to 250 V
Operational frequency range
45 to 65 Hz
Power supply circuit consumption (CPU board)
20 W maximum
Input fuse
125mA, 250V
PROBE INPUTS
Input measuring range
0 Ohm, open circuit
0-5000 mV
Maximum wire length
500 feet (150 m)
Recommended wires
2 strands, shielded, AWG #22
ALARM RELAY
Maximum current
1 A at 30 VDC
Delay before switching
30 seconds (approximate)
Fuse
1A 250VAC
COMMUNICATIONS PORTS
Maximum wire length
820 feet (250 m)
Recommended wire
2 strands, twisted pair, low capacity, shielded, AWG
#22
Important Notice:
-
It is important to have a backup system in case of a system failure.
-
Low-voltage and high-voltage wires must be passed through different conduits at
least 1 foot (30 cm) apart. If low-voltage and high-voltage conduits must be
crossed, the crossing must be at a 90-degree angle.
-
All wiring must be made by a certified electrician and conform to local electrical
regulations.
www.monitrol.com
Summary of Contents for GE-BIN4
Page 8: ...GE BIN4 INSTALLATION Section B 8 GE BIN4 INSTALLATION GE BIN4 SECTION B www monitrol com...
Page 18: ...GE BIN4 USER S GUIDE Section C 18 GE BIN4 USER S GUIDE GE BIN4 SECTION C www monitrol com...
Page 51: ...GE BIN4 INDEX WARRANTY GE BIN4 Section D 51 INDEX WARRANTY GE BIN4 SECTION D www monitrol com...
Page 55: ...www monitrol com...
Page 56: ...GE BIN4 VER 1 9 March 18 2020 www monitrol com...