10.
This parameter is used to identify a WiFarm network. A WiFarm network is formed
when the
RF NETWORK [9]
is set to the same value as the
RF ADDRESS [10]
of its RF communication card of the controller designated as the network master (ex.
WebGate in most installations). Other controllers can join the existing network by
adjusting
RF NETWORK [9]
to the
RF ADDRESS [10]
of that same network. To
adjust this parameter, place the cursor on the digit you wish to change and use the
+
and
–
buttons to change the value. When
RF CHANNEL [8]
is set to “
OFF
”, this
parameter will disappear. This parameter can be adjusted to any value from 00000 to
39999.
11.
This parameter displays the number (address) associated to the RF communication
card inserted in the controller. A unique number is given to each RF communication
card of the WiFarm network. There is a unique
RF ADDRESS [10]
associated to
each RF communication card. The
RF ADDRESS [10]
also appears on the sticker
present on the RF card. When
RF CHANNEL [8]
is set to “
OFF
”, this parameter
will disappear. The address can be any value from 0 to 32767.