GE-BIN4 USER’S GUIDE
GE-BIN4
Section C-33
5.
This parameter is used to set the maximum weight the bin can hold. This value will
be used to calculate the fill percentage of the bin. If this value is set to “
---
”,
%FILL BIN {1-4} [2]
4
will not be calculated and will also display “
---
”. This
parameter is adjusted in 10kg (10lb) increments from “
---
”, 100kg (100lb) to
30000kg (70000lb).
6.
This parameter is used to set the low weight limit for the bin. When the weight
measure for the bin is less than this value, the low limit alarm will activate.
Adjusting this value to “
OFF
” will deactivate the low limit alarm. This parameter is
adjusted in 1kg (1lb) increments from “
OFF
”, 1kg (1lb) to 30000kg (30000lb).
7.
This parameter is used to set the weight increase that will trigger a fill sequence.
When the weight of the bin increases by this value within a time period of
FILL
TIME [8]
, the fill sequence will begin. This parameter is adjusted in 1kg (1lb)
increments from 50kg (50lb) to 999kg (999lb).
8.
This parameter is used to set the time within which the weight must increase to
trigger a fill sequence, or remain stable to end the fill sequence. When the weight of
the bin increases by
FILL THRESHOLD [7]
within this time period, the fill
sequence will begin. When the weight of the bin does not increase by
TOLERANCE [4]
within this time period, the fill sequence will end. This
parameter is adjusted in 1-minute increments from 1 to 10 minutes.
9.
This parameter is used to indicate to the controller if the auger is present or not
present for the bin. If this parameter is set to “
Yes
”, the auger will be used to
calculate fill amounts and consumptions during a fill sequence. Auger run time will
also be recorded in its history and be monitored for the maximum auger run time
alarm. If this parameter is set to “
No
”, all auger-related parameters will disappear
and the auger will not be used in any calculation. Furthermore, the auger will not be
monitored for the maximum auger run time alarm.
10.
This parameter is used to reset the consumption reference to the actual weight. If the
SELECT
button is pressed while the cursor is positioned on this parameter, the actual
weight will be re-evaluated without considering
TOLERANCE [4]
and that weight
will be used as reference for future consumption reference. If a communication error
occurred during the operation, the message will change to “
Error (Comm)
”. If a
problem with a load cell occurred during the operation, the message will change to
“
Error (Load Cell)
”. If no problem occurred during the operation, the
message will change to “
Reset Done
”.
4
Refer to the
BIN INFO MENU (1)
screen for more information on this parameter.
www.monitrol.com
Summary of Contents for GE-BIN4
Page 8: ...GE BIN4 INSTALLATION Section B 8 GE BIN4 INSTALLATION GE BIN4 SECTION B www monitrol com...
Page 18: ...GE BIN4 USER S GUIDE Section C 18 GE BIN4 USER S GUIDE GE BIN4 SECTION C www monitrol com...
Page 51: ...GE BIN4 INDEX WARRANTY GE BIN4 Section D 51 INDEX WARRANTY GE BIN4 SECTION D www monitrol com...
Page 55: ...www monitrol com...
Page 56: ...GE BIN4 VER 1 9 March 18 2020 www monitrol com...