GE-BIN4 USER’S GUIDE
Section C-28
GE-BIN4
BIN {1-4} DETAILS
SUB SCREENS
1.
1-4.1
Some parameters may not appear if their corresponding option is not activated. To verify
these options, refer to the Feed Bin Scale Installation manual.
1.
These parameters display the percentage of the weight measured on each load cell. If
there is a communication problem with the bin’s module or one of the load cells in
not operating properly, the concerned parameters will display “
---
”.
2.
These parameters are used to set the gain of the load cells of the respective bin scale.
This value is the gain in mV for each Volt of excitement and must correspond to the
load cell manufacturer's specifications. These parameters are adjusted in 1mV
increments from 0mV to 781mV.
3.
These parameters are used to set the maximum weight of the load cells of the
respective bin scale. This value is the greatest weight the load cell can read and must
correspond to the load cell manufacturer's specifications. These parameters are
adjusted in 1kg increments from 0kg to 32767kg.
B i n 1 D e t a i l s
L C 1 : ( 1 0 % )
L C 2 : ( 3 2 % )
L C 3 : ( 2 1 % )
L C 4 : ( 1 0 % )
L C 5 : ( 1 0 % )
L C 6 : ( 1 7 % )
L C 7 : ( 1 0 % )
L C 8 : ( 1 7 % )
L C G a i n : 5 0 m V
L C M a x W e i g h t : 2 6 0 7 0 k g
[
1
]
[
2
]
[
3
]
www.monitrol.com
Summary of Contents for GE-BIN4
Page 8: ...GE BIN4 INSTALLATION Section B 8 GE BIN4 INSTALLATION GE BIN4 SECTION B www monitrol com...
Page 18: ...GE BIN4 USER S GUIDE Section C 18 GE BIN4 USER S GUIDE GE BIN4 SECTION C www monitrol com...
Page 51: ...GE BIN4 INDEX WARRANTY GE BIN4 Section D 51 INDEX WARRANTY GE BIN4 SECTION D www monitrol com...
Page 55: ...www monitrol com...
Page 56: ...GE BIN4 VER 1 9 March 18 2020 www monitrol com...