61
in.xe
™
"Pump 2 or blower
doesn't
work" steb-by-step
• If "Pump 2" or "Blower" does
not work in even when
indicator is on, replace Pump
2 fuse or the accessory fuse
for the blower.
• If replacing the fuse is not
effective, take voltage reading
on the corresponding
in.link™ connector.
Pump 2 fuse
• Turn "Pump 2" to
low speed
and take voltage reading
between:
240 VAC: Pin 6 & Pin 1
120 VAC: Pin 6 & Pin 5
Your reading should be:
240 VAC for a 240 VAC pump
120 VAC for a 120 VAC pump
120 VAC at P2 connector:
Pin 2 & Pin 5
240 VAC at P2 connector:
Pin 2 & Pin 1
240 VAC at P2 connector:
Pin 6 & Pin 1
Pin 6
Accessory fuse
Pin 2
Pin 2
Pin 1
Pin 5
Pin 1
120 VAC at P2 connector:
Pin 6 & Pin 5
Pin 6
Pin 5
• Turn "Pump 2" to
high speed
and take voltage reading
between:
240 VAC: Pin 2 & Pin 1
120 VAC: Pin 2 & Pin 5
Your reading should be:
240 VAC for a 240 VAC pump
120 VAC for a 120 VAC pump
• Turn "Blower" on and take
voltage reading between:
240 VAC: Pin 2 & Pin 1
120 VAC: Pin 2 & Pin 1
Your reading should be:
240 VAC for a 240 VAC blower
120 VAC for a 120 VAC blower
• If voltage is as it should be,
replace Pump 2 or blower.
• If not, replace Spa Pack.
* Only available on IN.XE-5-XX-XXX