36
in.xe
™
Parameter
Display
Options
Description
Output 2 current
1 to 15 amperes
Current draw of the accessory connected to the relay of Output 2A
Output 3 current
1 to 15 amperes
Current draw of the accessory connected to the relay of Output 3A
Output 4 current
1 to 15 amperes
Current draw of the accessory connected to the relay of Output 4A
Output 5 current
1 to 17 amperes
Current draw of the accessory connected to the relay of Output 5A
Direct current
0 to 5 amperes
Current draw of the Direct output
Minimum input
current
10 to 20
Minimum input current (breaker size)
Number of phases
1 or 2 (UL)
1, 2 or 3 (CE)
Number of Phase / Breaker
Input current
10 to 60A Single Phase (UL and CE)
10 to 48A Dual Phase (UL)
10 to 40A Dual Phase (CE)
10 to 20A Triple Phase (CE)
Available household current
--
--
--
--
--
--
--
--
Number of Phases selection
UL
Menu not available
CE
1 or 2
UL Swim
1 or 2
CE Swim
1, 2 or 3
Maximum Input Current
1 phase 2 Phases
3 Phases
UL
48
na
na
CE
40
20
na
UL Swim
60
48
na
CE Swim
60
40
na
Table 3
programming the in.xe™