59
in.xe
™
Problem
solved.
"Pump 2 or blower
doesn't
work" flow chart
Have any error
messages
(OH, HR, etc.)
appeared on
keypad display?
yes
no
Verify if low level
programming is set
properly.
Does “Pump 2” or
"Blower" indicator
appear on keypad
display when you
press Pump 2 or
blower key?
Refer to specific
section indicated
by error message.
yes
no
Replace
keypad.
no
Replace
Blower fuse.
Pump 2 still
not working!
Is Pump 2
or blower
working?
yes
If still not
working
replace
Spa Pack.
no
Measure
voltage on
the board.
Do you get
a 240 VAC
reading (or
120 VAC for
a 120 VAC
pump)?
yes
no
Replace
Pump 2
or blower.
Replace
Spa Pack.
yes
If Pump 2 or blower is not working,
follow this troubleshooting flow chart:
* Only available on IN.XE-5-XX-XXX