17
in.xe
™
Heat.wav™ heater
In.xe™ comes with a high
performance heat.wav™ heater.
With no pressure switch, it
features in.flo™ integrated dry-
fire protection.
The heat.wav™ heater is factory configured 240 V /4 kW (or
2KW), but it can be converted to a dedicated 120 V / 1kW by a
simple switching a cable connection port. (Option available on
NorthAmerican models only).
Heat.wav™ specification summary:
• Supports 120 V or 240 V
• Protected by external
breaker (not fused)*
• Incoloy® or Titanium (optional) heater element
for greater protection against corrosion.
Connections for 120 V
heater (1KW)
L2
Ground
L1
Connections for 230/240
VAC heater (4KW or 2 KW)
heater connections
*Note: European models are 230 or 240 VAC and are fuse protected
A watertight panel protects
the heater and probe
connectors. Removing the
panel gives access to in.flo™
dry-fire protection and hi-limit/
regulation probe connectors,
line 1, line 2 and ground power
input cables connection ports.
Ground
N
L1