Fig.21
4.
Remove the adjusting mandrel (6)
®
Done
6.7.2.3 Fitting the proximity switch
Carry out the following steps:
1.
Screw in the proximity switch M12 (8) together with the lock nut (11) into the
sliding piece through to the double-disk (7).
Fig.22
®
Done
6.7.2.4 Set the proximity switch
Carry out the following steps:
1.
Unscrew the proximity switch (8) by one full turn (360°) to set the gap (a) to
approx. 1 mm.
Assembly and installation
Electrical connection with T.VIS control top
430BAL009261EN_2
17.04.2023
43