2.
Set the sensor (S1) by turning the adjusting screw (1) clockwise over the
switchpoint until the LED (D1) goes off.
Switch setting sensor 1
Carry out the following steps:
1.
Set the sensor (S1) by turning the adjusting screw (1) anticlockwise to the
switchpoint until the LED (D1) shines green.
2.
Also position sensor (S2) with the adjusting screw (1) by one anticlockwise
turn.
3.
Tighten the lock screw (2).
®
Done
Control position valve (main stroke)
Prerequisite
•
Move the valve disk to the controlled position by electrically or manually
actuating the solenoid valve Y1.
Carry out the following steps:
1.
Release the lock screw (2).
Fig.16
Presetting sensor 2
Carry out the following steps:
1.
Set the sensor (S2) by turning the adjusting screw (1) clockwise to the
switchpoint until the LED (D1) shines yellow.
2.
Set the sensor (S2) by turning the adjusting screw (1) clockwise over the
switchpoint until the LED (D1) goes off.
Setting the switchpoint sensor 2
Carry out the following steps:
1.
Set the sensor (S2) by turning the adjusting screw (1) anticlockwise to the
switchpoint until the LED (D1) shines yellow.
Assembly and installation
Electrical connection with T.VIS control top
430BAL009261EN_2