2.
Also position sensor (S2) with the adjusting screw (1) by one anticlockwise
turn.
3.
Tighten the lock screw (2).
4.
De-activate the solenoid valve Y1.
®
The valve disk moves to the non-actuated position.
®
The yellow LED (D2) goes off and the green LED (D1) shines.
5.
Attach the cap (7) and tighten the Philips screws (25).
®
Done
Fig.17
6.7.2
Adjustment of the initiators in the lantern
Hint!
Only in combination with T.VIS A-15 / M-15.
6.7.2.1 Fitting the sliding piece
Carry out the following steps:
1.
Position the nut (2) against the slot (4.1) in the lantern (4) from the inside and
hold it in position with a finger.
Fig.18
2.
Attach the sliding piece (1) with the countersunk screw (3) with the assembly
borehole (1.1) in the direction shown pointing toward the housing (5).
Assembly and installation
Electrical connection with T.VIS control top
430BAL009261EN_2