Notice
Sensitive parts
The surfaces of the valves and double-disks are sealing surfaces and may
not be damaged.
► Carefully lower the valve into the housing.
Tools required:
•
Philips screwdriver
•
Slotted screwdriver
Carry out the following steps:
1.
Guide the valve insert (A) carefully into the housing.
2.
Remove the cap from the control top (B) with the Philips screwdriver.
3.
Control the lift stroke via the manual actuator (Y1).
4.
Grease the thread of the clamp connections (43) and install.
®
! Ensure that the clamp connections (43) are firmly installed.
®
! Observe torques, see table “Tightening torques'', Section 10.6.1, Page 69
5.
De-energize the manual actuator (Y1).
6.
Establish the pneumatic hose connection between the lifting actuator (L) and
control top (B).
7.
Establish the electrical connection (176) between the proximity switches
(170).
8.
Attach the hood with the Philips screwdriver and a tightening torque of 1 Nm
on the control top (B).
®
Done
Maintenance
Installation
430BAL009261EN_2
17.04.2023
81