![GEA VARIVENT 24/7 PMO Operating Instructions Manual Download Page 70](http://html2.mh-extra.com/html/gea/varivent-24-7-pmo/varivent-24-7-pmo_operating-instructions-manual_4040552070.webp)
Fig.36
2.
Rated widths up to 2'' DN:
Grease the thread of the clamp connection (43)
and attach the lantern (9) on the lift (L1) with the clamp connection (43).
Rated widths from 2.5'' DN:
Attach the lantern (9) with hex screws (110) on
the lifting actuator (L1) with a jaw wrench.
®
Ensure that the clamp connection (43) is firmly installed.
®
! Observe “torques” table, see Section 10.6.1, Page 69
Maintenance
Installation
430BAL009261EN_2
70
17.04.2023