10.5.4 Removing the valve disk
Fig.29
Tools required:
•
Hex socket key
•
Socket wrench (hex ring wrench)
•
Open-ended wrench
Carry out the following steps:
1.
Release the clamp connection (46).
2.
Remove the drive (A) from the lift drive (L1).
3.
Lift the locking flange (L) from the lift drive.
Maintenance
Disassembly
430BAL009261EN_2
17.04.2023
63