Maintenance
Inspections and preventive maintenance
7821-9001-005
01. October 2019
● Take the hose out of the housing cover.
● Insert a new hose in the housing cover.
● Screw the housing cover onto the hose pump.
Attention!
Not fitting the housing cover properly can damage
the hose or cause fluctuation of the pump output.
► Make sure that the housing cover is positioned
correctly between the guide marks (x)!
- The housing cover must be flush
x
● Reconnect the hoses to the outside of the hose pump.
The pump can now be used again.
Note
After replacing the hose, reset the sample quantities required on the unit and
carry out a trial run.