Sampling device
Prepare for sampling
7821-9001-005
01. October 2019
Assemble the sample tank
The sample tank must be assembled
before it is installed.
1
2
Attention!
Sample suction error
If the ball catch (1) is not seated properly under the lid, the balls do not block
the holes in the lid properly when the sample is being sucked from the tank.
► Check that the ball catch is seated properly(1).
● Loosen the nuts, if necessary (2)
● Align the ball catch and retighten the nuts(1, 2)
● Fit Y-hose connectors.