Sampling device
Clean
7821-9001-005
01. October 2019
5.10
Clean
The milk-carrying parts of the installation are cleaned fully automatically by the
automatic milking system.
Note
Carry out cleaning directly before and after sampling.
Cleaning is performed with the individual phases of the system clean (pre-rinse,
main clean and final rinse) and also with the short clean.
Warning!
Risk of scalding by hot cleaning solution!
Hot steam generated during the main system clean can cause scalding if the
device cover is left open!
► Do not open the cover during the main system clean.
● The hose pump runs several times for approximately 1 minute and remains
stationary briefly.
● The mixing valve opens and the hoses are drained by the incoming air.
Please note!
The red suction hose should be
disconnected from the lid of the
sample tank at the end of the
system clean and placed in a
vessel containing hot water. The
pump in the sampling case should
then be operated using the
”Pump” button for about 1 minute
to flush residual milk from the
suction hose.
Also clean the sampling device manually, inside and out, after each session.
● Never clean electrical equipment with water or similar fluids.
Attention!
Damage can be caused if fluid gets in!
Protect any electrically conductive components from the effects of moisture.
► Do not clean the sampling device with a high pressure cleaner or jet of
water!
● Clean the sampling equipment in the case lid with a damp cloth and then wipe
dry.
● Clean the plastic case and the stainless steel components in the bottom of the
case with a brush or sponge and warm cleaning solution.
Next wipe with a clean, damp cloth and then wipe dry.
Note
Empty bottle racks and the drain channels can be cleaned in a dish washer.