– 52 –
Evaporator
WARNING:
Sharp edges may be exposed when
servicing. Use caution to avoid injury. Wear Kevlar
gloves or equivalent protection.
The 30-in. Built-in Monogram Convertible Unit
evaporator requires the use of LOKRING for
replacement due to aluminum tubing.
There are 2 methods for replacement or repair of
the evaporator depending on the leak location.
Method #1:
Leak in the evaporator or the factory
LOKRING connection. (No leak at capillary tube
joint.)
1. Remove or relocate the red tape located to the
right of both factory ring connectors.
4. Install the new evaporator and mark the
replacement tubing to the length of the cabinet
tubing.
2. Clean the tubing with emery cloth or Scotch-
Brite™ pad.
3. Cut the tubing close to the right side of the
factory ring connectors
Note:
In the following step, tubing should be cut to
provide an overlap of the 2 tubes. (This allows for
the tubing to bottom out in the connector and holds
the connector in place while applying the tool.)
5. Clean the replacement evaporator tubing with
emery cloth or Scotch-Brite pad and cut to
length.
(
Continued next page
)