Masoneilan SVI II AP Digital Positioner Quick Start Guide
=
|
41
© 2015 General Electric Company. All rights reserved
.
Figure 21
Magnet Orientation for Camflex and Varimax with Valve Closed
Figure 22
Magnet Orientation for 90° Valve Rotation with Valve Closed
Using ValVue to Check Magnet Position
Use this procedure to check the magnet using ValVue.
1. Connect to the positioner in accordance with the ValVue instructions.
After the positioner has been installed and set up with a HART
®
Modem in a
HART
®
compliant communications loop, install ValVue on the computer that
is connected to the HART
®
modem.
Run ValVue.
Select the installed positioner from the list of Connected Devices.
Select the:
Check
tab to view the current operating conditions of the selected
positioner.
2. Read Raw Sensor Data:
When the valve is closed the value should be between – 1000 and +1000 for
a reciprocating valve or a 60° rotation rotary valve.
When the valve is at mid-travel the value should be between –1000 and
+1000 for a greater than 60° rotation rotary valve.
Magnet
Axis
with
Valve
Closed
Magnet
Axis
with
Valve Closed
Clockwise to Close
Clockwise to Open
45
¬