Masoneilan SVI II AP Digital Positioner Quick Start Guide
=
|
27
© 2015 General Electric Company. All rights reserved
.
Figure 12
Reciprocating Linkage
10. Thread the turnbuckle onto the left hand threaded rod end (Figure 12).
11. Adjust the turnbuckle until the hole in the SVI II AP lever is aligned with the
indicating hole in the bracket. Tighten both turnbuckle lock nuts. Refer to
Figure 11.
12. For reciprocating valves the adjustable link turnbuckle must be parallel to the
valve stem. To ensure linearity in positioning, verify that the hole in the lever aligns
with the indicating hole in the bracket when the valve is in the closed position.
Check that the bracket is mounted using the proper holes. (Refer Table
4 on
page
28.)
13. Mount the SVI II AP to the bracket and secure with four M6 socket head cap
screws.
Figure 13
Lever for Masoneilan Model 87/88 Multispring Actuator