5–20
MULTILINK ML810 MANAGED EDGE SWITCH – INSTRUCTION MANUAL
SYSTEM CONFIGURATION
CHAPTER 5: IP ADDRESSING
FIGURE 5–4: Displaying configuration for different modules.
Note – multiple modules can be specified on the command line
5.4.4
Saving Configuration
It is advisable to save the configuration before updating the software, as it may be
necessary in certain situations. The
loadconf
command requires a reboot to activate the
new configuration. Without a reboot, the ML810 used the previous configuration. When
reboot is selected, the user is prompted as follows:
Reboot? ['Y' or 'N']
Select “Y”. The ML810 will prompt:
Save Current Configuration?
Select “N”.
ML810#
show config module=snmp,system
[HARDWARE]
type= ML810
slotB=8 Port TP Module
##########################################################
# System Manager - This area configures System related #
# information. #
##########################################################
[SYSTEM]
***Edit below this line only****
system_name=Main
[email protected]
system_location= Markham, Ontario
boot_mode=manual
system_ip=192.168.1.15
system_subnet=0.0.0.0
system_gateway=192.168.1.11
idle_timeout=10
telnet_access=enable
snmp_access=enable
web_access=enable
--more—
...