MULTILINK ML810 MANAGED EDGE SWITCH – INSTRUCTION MANUAL
B–1
Multilink ML810
Appendix B: DC Power Input
GE
Digital Energy
DC Power Input
B.1
Specifications for Multilink ML810 Switches, DC Power at 12, 24, –48, 125
and 250 VDC Power input
Each Multilink ML810 Managed Switch requires DC power input, at 12, 24, 48, 125 and 250
V DC nominal. The wide range of DC power input types qualifies this product for use in 12,
24, 48, 125 and 250 V DC applications in different industries.
DC Power Terminals: “+”, “
-
”
are
internally floating so that user may ground either.
Figure B-1: Location of chassis ground
Power Consumption:
15 watts typical (for a fully loaded fiber model with 2Gb)
10 watts typical (for 8 ports, copper and 100Mb fiber)
12VDC Power Input nominal (range 10 to 15VDC)
24VDC Power Input nominal (range 18 to 36VDC)
-48VDC Power Input nominal (range 36 to 60VDC)
Location of Chassis
Ground