SETTING PARAMETERS
CHAPTER 5: IP ADDRESSING
The
edit
button allows editing of the SNTP parameters as shown below. Adding or deleting
SNTP servers is accomplished by using the add and delete buttons. Clicking the edit button
allows the specific SNTP parameter settings to be modified.
After the proper SNTP values are entered, click
OK
to register the changes, or click
Cancel
to back out from the changes made.
To add an SNTP server, click the
add
button on the
Configuration > SNTP
menu. The menu
prompts you to add IP address of an SNTP server, the time out in seconds and the number
of retries, before the time synchronization effort is aborted. The
Sync Now
button allows
synchronization as soon as the server information is added.
NOTE
Note
If your site has internet access, there are several SNTP servers available online. A quick
search will yield information about these servers. You can use the IP address of these
servers; however, please ensure the server can be reached by using the
ping
command.
The
ping
command can also be launched from the EnerVista software.