05-4446A01, Rev. C
Mercury Reference Manual
79
Operation and Data
Flow
• Communicate with RTU A by Telneting to Remote 1, port 30010.
• Communicate with RTU B by Telneting to Remote 2, port 30010.
• Communicate with RTUs C and D by sending and receiving data
from the Access Point’s
COM
port.
• All communication paths can be used simultaneously.
Invisible place holder
Figure 3-43. Mixed-Modes Application Diagram
EIA-232
Terminal
or Computer
RTU–C
EIA-232
EIA-232
EIA-232
RTU–D
EIA-232
Ethernet
Crosssover
RTU–B
RTU–A
Access Point
Transceiver
LA
N
COM
1
COM
2
PW
R
LIN
K
Remote 1
LA
N
COM
1
COM
2
PW
R
LIN
K
Remote 2
LA
N
COM
1
COM
2
PW
R
LIN
K
Remote 3
LA
N
COM
1
COM
2
PW
R
LIN
K
Remote 4
Table 3-7. Serial Port Application Configuration
Transceiver Location
Menu Item
Setting
Access Point
Status
Enabled
Baud Rate
9,600
Flow Control
Disabled
IP Protocol
UDP
Send to Address
A multicast IP address such as
224.254.1.1
Send to Port
30010
Receive on Port
30010
Receive on Address
0.0.0.0 (Not Used)
Remote Units 1 & 2 (COM1)
Status
Enabled
Baud Rate
2,400
Flow Control
Disabled
IP Protocol
TCP
Receive on Port
30010
Remote Units 3 & 4 (COM1)
Status
Enabled
Baud Rate
9,600
Flow Control
Disabled
IP Protocol
UDP
Send to Address
IP address of the AP
Send to Port
30010
Summary of Contents for MDS Mercury Series
Page 2: ......
Page 10: ...2 Mercury Reference Manual 05 4446A01 Rev C ...
Page 28: ...20 Mercury Reference Manual 05 4446A01 Rev C ...
Page 36: ...28 Mercury Reference Manual 05 4446A01 Rev C ...
Page 140: ...132 Mercury Reference Manual 05 4446A01 Rev C ...
Page 142: ...134 Mercury Reference Manual 05 4446A01 Rev C ...
Page 156: ...148 Mercury Reference Manual 05 4446A01 Rev C ...
Page 168: ...160 Mercury Reference Manual 05 4446A01 Rev C ...
Page 184: ...176 Mercury Reference Manual 05 4446A01 Rev C ...
Page 194: ...I 10 Mercury Reference Manual 05 4446A01 Rev C ...