TABLE 5: Terminal Identification/Function
Terminal Terminal
Label
Name
Function
POWER TERMINAL BOARD
, L2,
L3
AC Supply Line
Input Terminals
Output
T e r m i n a l s
Connection for
power (200-230
or 380-460
3-phase; 5060 Hz
L2 for single phase Input.)
Connection for 3-phase induction motor
P+, DB
External Braking
Resistor
Connection for external braking resistor.
(Only on
Hp to 5 Hp.)
1 1
1 2
1 3
Cl
CM
FWD
REV
THR
Frequency Setting
Common terminal for terminals 12, 13, Cl (Do not
Common Terminal
connect to CM terminal or electrical noise immunity may be lost )
Frequency Setting
Voltage Input
When 0 to
Vdc (0 to
IS
input, the maximum frequency is
reached at
Vdc
and is proportional to output frequency
down to 0 Vdc. Input impedance
IS
22K ohm.
gain setting
Frequency Setting
Regulated
Vdc power supply for frequency setting potentiometer,
Voltage Output Term
or less (13 to terminal 11.)
Frequency Setting
Current Input (+)
When the
signal is
to
dc, the maximum frequency is
reached at 20mA and
IS
proportional down to a minimum frequency
setting at 4mA. Input impedance is 250 ohm Must be isolated source
Control Circuit
Common terminal for control
commands, and FMP pulse
Common Terminal
output signal. (Do not connect to terminal 1
Forward Command
Input Terminal
Reverse Command
Input Terminal
Forward command via FWD-CM (closed). Reverse command via
REV-CM (closed). When FWD-CM
IS
closed and REV-CM
IS
closed
at the same time, the Drive will decelerate to stop.
Motor Coast-To-Stop
Input Terminal/Reset
Input
Motor will coast-to-stop with BX-CM (closed)
(For use when
applying mechanical brake with Drive
operation.) Note. If
BX-CM is opened with FWD or REV closed, the Drive will start
operating
External thermal trip
c o m m a n d
CONTROL TERMINAL BOARD
After removal of fault
Faults are reset when a momentary
contact closure is made between the RST-CM terminals for more
than 0.1 seconds.
NOTE:
If there
an
to the FWD and/or REV terminals, the unit
not RESET.
With THR-CM (open), OH trip
occur and the motor will
coast-to-stop.
NOTE:
With no external thermal relay or external braking resistor
thermostat,
THR-CM
must be closed or the
not operate.
4-8
Summary of Contents for Fuji Electric MICRO-SAVER AF-300
Page 1: ...AF 3W MICRO AVER TM Drives l 4 5 Horsepower Instructions...
Page 5: ......
Page 17: ......
Page 19: ...AF 300 MICRO A VER Dimensions Figure 1 Figure 2 Figure 3 Figure 4 Note Inches MM 3 2...
Page 33: ......
Page 64: ......
Page 72: ......
Page 76: ......
Page 77: ......