![GE Multilin F35 Instruction Manual Download Page 393](http://html.mh-extra.com/html/ge-multilin/f35/f35_instruction-manual_572024393.webp)
GE Multilin
F35 Multiple Feeder Protection System
B-43
APPENDIX B
B.4 MEMORY MAPPING
B
IEC 61850 Configurable GOOSE Transmission (Read/Write Setting) (8 modules)
B5A0
IEC 61850 Configurable GOOSE Function
0 to 1
---
1
F102
0 (None)
B5A1
IEC 61850 Configurable GOOSE ID
---
---
---
F209
“GOOSEOut_x_”
B5C2
Configurable GOOSE Destination MAC Address
---
---
---
F072
0
B5C5
IEC 61850 Configurable GOOSE VLAN Transmit Priority
0 to 7
---
1
F001
4
B5C6
IEC 61850 Configurable GOOSE VLAN ID
0 to 4095
---
1
F001
0
B5C7
IEC 61850 Configurable GOOSE ETYPE APPID
0 to 16383
---
1
F001
0
B5C8
IEC 61850 Configurable GOOSE ConfRev
1 to 4294967295
---
1
F003
1
B5CA
Configurable GOOSE Dataset Items for Transmission
0 to 256
---
1
F232
0 (None)
B60A
...Repeated for Module 2
B674
...Repeated for Module 3
B6DE
...Repeated for Module 4
B748
...Repeated for Module 5
B7B2
...Repeated for Module 6
B81C
...Repeated for Module 7
B886
...Repeated for Module 8
IEC 61850 Configurable GOOSE Reception (Read/Write Setting) (8 modules)
B900
Configurable GOOSE Dataset Items for Transmission
0 to 128
---
1
F233
0 (None)
B940
...Repeated for Module 2
B980
...Repeated for Module 3
B9C0
...Repeated for Module 4
BA00
...Repeated for Module 5
BA40
...Repeated for Module 6
BA80
...Repeated for Module 7
BAC0
...Repeated for Module 8
Contact Inputs (Read/Write Setting) (96 modules)
BB00
Contact Input 1 Name
---
---
---
F205
“Cont Ip 1“
BB06
Contact Input 1 Events
0 to 1
---
1
F102
0 (Disabled)
BB07
Contact Input 1 Debounce Time
0 to 16
ms
0.5
F001
20
BB08
...Repeated for Contact Input 2
BB10
...Repeated for Contact Input 3
BB18
...Repeated for Contact Input 4
BB20
...Repeated for Contact Input 5
BB28
...Repeated for Contact Input 6
BB30
...Repeated for Contact Input 7
BB38
...Repeated for Contact Input 8
BB40
...Repeated for Contact Input 9
BB48
...Repeated for Contact Input 10
BB50
...Repeated for Contact Input 11
BB58
...Repeated for Contact Input 12
BB60
...Repeated for Contact Input 13
BB68
...Repeated for Contact Input 14
BB70
...Repeated for Contact Input 15
BB78
...Repeated for Contact Input 16
BB80
...Repeated for Contact Input 17
BB88
...Repeated for Contact Input 18
BB90
...Repeated for Contact Input 19
BB98
...Repeated for Contact Input 20
BBA0
...Repeated for Contact Input 21
BBA8
...Repeated for Contact Input 22
BBB0
...Repeated for Contact Input 23
BBB8
...Repeated for Contact Input 24
BBC0
...Repeated for Contact Input 25
BBC8
...Repeated for Contact Input 26
Table B–9: MODBUS MEMORY MAP (Sheet 36 of 48)
ADDR
REGISTER NAME
RANGE
UNITS
STEP
FORMAT
DEFAULT
Summary of Contents for F35
Page 2: ......
Page 4: ......
Page 296: ...5 174 F35 Multiple Feeder Protection System GE Multilin 5 9 TESTING 5 SETTINGS 5 ...
Page 328: ...7 8 F35 Multiple Feeder Protection System GE Multilin 7 2 TARGETS 7 COMMANDS AND TARGETS 7 ...