31
How to place dishes correctly
Dishes must be placed in the middle of a warming zone. The circle markings exactly show the middle of each
warming zone and should be located ideally under the mid
Otherwise, the dish may
not be recognized by the device or only little energy will be provided.
When placing dishes on top of the device or when putting them down, please take care that the edges of the dish
will not scratch or damage the glass.
Assembly and Safety Instructions
The assembler must make sure, that the device is still approachable after installing to allow service and
maintenance.
There must not be drawers, which are opened to the top, underneath the inductive elements.
The built-in device must be provided with enough space to the bottom side to ensure sufficient air
ventilation.
The maximum intake air temperature must not exceed 40°C in front of the cooling fans.
Having a sufficient air supply system you have to ensure that already heated air does not get sucked in
by the devices again.
Please handle the sensitive glass with great care as you can see scratches after installation.
There must not be any flammable nor explosive objects beneath the inductive elements.
Please mind that small parts can get sucked in.
The devices must be installed / placed with a distance to the rear or side wall or other appliances of at
least 5 cm (side) and 10cm (bottom).
Please ensure that the removal of the plug is to be such that an operator can check from any of the
points to which he has access that the plug remains removed.
Make sure, the cut-out gap after installation is filled with silicon to protect against water or other liquids
ingress.
Summary of Contents for InductWarm 20
Page 4: ...4...
Page 15: ...15 Einbauzeichnung Mindestabstand bei Einbau mehrerer Module R 7 mm...
Page 19: ...19 EG Konformit tserkl rung Serie 200...
Page 20: ...20...
Page 32: ...32 Overview Drawing Minimum distance when installing numerous units R 7 mm...
Page 33: ...33 Air cooling ventilation...
Page 36: ...36 EG Declaration of Conformity InductWarm 200...
Page 48: ...48 Plans d ensemble Distance minimale R 7 mm Connexion du cordon d alimentation...
Page 49: ...49 A ration...
Page 52: ...52 CE D claration de conformit s rie 200...
Page 53: ...53...