24
supply must be performed by an authorized and locally recognized installer by
keeping the existing specifications.
Before connecting the appliance, check that the connection data on the data plate
(voltage and connected load) match the mains electricity supply.
1.3.1 Installation suggestions
• Open the package. Before setting up the appliance, check it for any externally
visible damage due to transportation. If in any doubt, call for a specialist to
check it (from the authorized local dealer who sold the appliance).
• Place the dishwasher at the installation area, close to the necessary water and
power supply (the ground should be sufficiently stable).
• The appliance should be placed horizontally. Possible inclinations should be
corrected using a spirit level.
• Following the successful installation, the dishwasher should be cleaned
thoroughly with a conventional detergent before it is put into operation.
1.4 Connection to the water supply
ATTENTION:
The connection with the water supply should be made according to
the current safety standards.
The dishwasher may be connected to water supply with maximum inlet
temperature 55o C/130o F. In case you need connection with water supply of
high temperature please contact our Factory or our distributor or our local
dealer.
• The water supply hose should have a flap valve (non-return valve) according to
DIN 1988.
• The water supply hose/pipe should be rinsed before the appliance’s connection.
• The water supply hose/pipe should have a minimum internal diameter of 16
mm and the connection with the hose should be 3/4 inch.
• All hose collars should be adjusted in a fixed position before the appliance is put
into operation.
ATTENTION:
The water pressure must be between 2 and 5 bar.
DE - Original
1.4.1 Drainage connection
The outflow is accomplished through gravity force (natural flow). The outlet hose
should be connected either directly to the main drainage - where a pipette for
odours is anticipated, or water runs directly to a drainage well in the ground,
which has a pipette for odours.
ATTENTION:
The outlet hose should not be placed higher than a level (as given for
each appliance’s type) from the lower side of the dishwasher’s dispenser.
1.5 Electrical Network connection
ATTENTION:
All electrical work must be carried out by a suitably qualified and
competent person.
The dishwasher operates under specific voltage depending on the type of the
dishwasher.
You should supply the power, depending on the appliance’s power reception (the
electrical connection should be made by authorized electricians).
Specifications should be met according to the corresponding parts of DIN, VDE,
D100, the EVU connection terms, the relevant ZH 1/37, chapter 7.2 - as well as the
current specifications for accident prevention.
Respectively, the appliance must be connected to a direct power supply electrical
installation through an HO7 RN-F cable with load relief of the appliance.
1.5.1 Protective duct connection and voltage compensation
The electrical safety of this appliance is ensured only if the protective duct has
been connected and checked properly. The corresponding specifications should
be met at this point (see paragraph 1.5).
In addition, the appliance should include a voltage compensation system. For this
reason, the backside of the appliance has a screw with the indication «voltage
compensation».
Following the electrical connection, the action of the protective duct, the voltage
compensation and the insulation value should be checked according to the
existing provisions of DIN VDE.