ANITA ©
8
3.4) Resistance box for knee-lifting solenoid
Installation:
a) Attach the resistance box around the motor under the table.
b) Connect the connector from the solenoid to the resistance box as shown in Fig. 3, and then connect
the line from the resistance box to the control box.
(Fig. 3)
Caution
►Plug in only after oil supply is finished. If the operator mistakenly steps on the pedal
with the plug in, the machine will start automatically and can cause severe injuries.
►When handling lubricants, wear protective glasses or gloves to avoid contact with your
eyes or skin. Inflammation may be caused otherwise. Never drink lubricants since they
can cause vomiting or diarrhea. Keep out of the reach of children.
►Operate the machine only after adding oil when the machine is being used for the
first time or has been left unused for a long time.
3.5) Lubrication
1. Installing Magnetic Chip Remover
A. Attach the magnetic chip remover that is in the accessory box to the oil pump inside the bed.
(Fig. 4)
►Do not use the magnet for other purposes. Use of the sewing machine without the magnet may
cause malfunction and has a bearing on the machine´s durability.
2. Lubricating the oil fan
!
Summary of Contents for GF-1116 Series