background image

Part # 4530868 (04/25/12)

Page 4

DIMENSIONS AND SPECIFICATIONS

STANDARD GRATE AVAILABLE IN ONE-SIDED OR TWO-SIDED STYLES

17-7/16in

451mm

OVERALL

HEIGHT

4.-11/16in

119mm

LEG WIDTH

TYP

LEG PITCH

"D"

14-13/16in

376mm

COOK HEIGHT

OVERALL

WIDTH

"E"

HEEGM48CL SHOWN

2-3/4in

68mm

3/4" NPT

GAS INLET

COOK WIDTH

"C"

3-7/8in

97mm

ELECTRICAL

23-7/16in

596mm

COOK DEPTH

3-5/8in

93mm

TROUGH

DEPTH

38-13/16in

986mm

OVERALL

DEPTH

8-13/16in

224mm

RAIL DEPTH

3-1/2in

89mm

1-1/8in

30mm

4.-3/4in

121mm

STANDARD

GRATE WIDTH**

RAIL FITS 1/3 PANS

**OPTIONAL FAJITA RACK REQUIRES THE REMOVAL OF 2 STANDARD GRATES

1-11/16in

43mm

ELECTRICAL

2-1/2in

63mm

3/4" NPT

GAS INLET

1-1/8in

28mm

28-15/16in

735mm

LEG DEPTH

7-7/8in

199mm

VALVE HEIGHT

10.4°

2ND GRATE

POSITION

2.2°

STANDARD

GRATE POSITION

Model # 

Shipping Dimensions: In. (mm)

No. Of 

Burners

Total BTU*

Shipping 

Weight Lbs/Kg

Shipping 

Size CuFT/

Cu/m

Width 

Depth

Height

Natural

Propane

HEEGM24CL

45/1143

45/1143

25-1/2/648

4

58,000

52,000

280/127

29.9/0.846

HEEGM36CL

45/1143

45/1143

25-1/2/648

6

87,000

78,000

420/191

29.9/0.846

HEEGM48CL

65/1651

45/1143

25-1/2/648

9

130,500

117,000

254/560

43.2/1.223

HEEGM60CL

65/1651

45/1143

25-1/2/648

11

159,500

143,000

700/318

43.2/1.223

TOTAL BTU BASED ON MANIFOLD OPERATING PRESSURE SPECIFIED IN TABLE BELOW AND APPLY TO INSTALLATIONS UP TO 

2000 FT (610m).

Model

COOK WIDTH "C"

LEG PITCH "D"

OVERALL WIDTH "E"

GREASE TRAY

24"

19-7/8in (506mm)

14-1/4in (362mm)

23-1/2in (597mm)

SINGLE

36"

29-7/8in (760mm)

24-1/4in (616mm)

33-1/2in (851mm)

SINGLE

48"

43-7/8in (1115mm) 36-1/4in (972mm)

47-1/2in (1207mm)

DUAL 

60"

53-7/8in (1369mm 48-1/4in (1222mm)

57-1/2in (1461mm)

DUAL

Models

Manifold Operating Pressure 

 

w.c.(Mbar)

Manifold Supply Pressure 

 

w.c.(Mbar)

Clearance to non- 

combustible material

Natural Gas

Propane

Natural Gas

Propane

Rear (in/mm)

Sides (in/mm)

All Models

4.5(11.2)

10.0(25.0)

7.0(17.4)

11.0(27.5)

0/0

0/0

*GAS INLET PIPE IS 3/4" NPT ON ALL MODELS

Model

ELECTRICAL REQUIREMENTS

Voltage

Frequency

Current

Cord

HEEGM24&36CL

120

50-60 Hz

0.10 A

NEMA 5-15P

220-240

50-60 Hz

0.05 A

NOT SUPPLIED

HEEGM48&60CL

120

50-60 Hz

0.22 A

NEMA 5-15P

220-240

50-60 Hz

0.11 A

NOT SUPPLIED

*WIRING DIAGRAMS PROVIDED WITH EACH UNIT

Summary of Contents for HEEGM XX CL

Page 1: ...0 USA Sales Parts and Service 1 800 424 2411 Canadian Sales 1 888 442 7526 Canada or USA Parts Service 1 800 427 6668 Part 4530868 04 25 12 2012 Garland Commercial Ranges Ltd FOR YOUR SAFETY DO NOT ST...

Page 2: ...uld expose you to airborne particles of glass wool ceramic fibers Inhalation of airborne particles of glass wool ceramic fibers is known to the state of California to cause cancer Operation of this pr...

Page 3: ...STALLATION 6 General 6 Positioning and Setup 6 Optional Stand 7 Air Supply and Ventilation 7 Electrical Connection 7 Gas Connection 8 Start Up 8 USE AND CARE 9 Operation 9 Warnings 11 Optional Equipme...

Page 4: ...EGM36CL 45 1143 45 1143 25 1 2 648 6 87 000 78 000 420 191 29 9 0 846 HEEGM48CL 65 1651 45 1143 25 1 2 648 9 130 500 117 000 254 560 43 2 1 223 HEEGM60CL 65 1651 45 1143 25 1 2 648 11 159 500 143 000...

Page 5: ...vidually controlled by a manual high low valve 9 ft power cord with NEMA 5 15P plug for standard 120V models Wire brush and scraper combination tool included for cleaning grates gas regulator for appl...

Page 6: ...e rating plate contains other important information critical to the proper installation of the unit It specifies the gas type gas pressure voltage and clearance requirements for the appliance INSTALLA...

Page 7: ...T USE AN EXTENSION CORD TO CONNECT THIS UNIT TO A POWER SUPPLY DO NOT USE THIS APPLIANCE IF THE POWER CORD IS DAMAGED DO NOT ATTEMPT TO REPAIR A DAMAGED POWER CORD TAKE CARE NOT TO EXPOSE THE POWER CO...

Page 8: ...ING IS REQUIRED INSTALL IN ACCORDANCE WITH LOCAL CODES 3 A certified flexible gas hose and quick disconnect assembly with suitable strain relief is recommended for connection from the gas supply line...

Page 9: ...TURN THE POWER OFF AND CLOSE THE MANUAL SHUT OFF VALVE TO THE APPLIANCE CONTACT AN AUTHORIZED SERVICE AGENT FOR SERVICE BEFORE ATTEMPTING TO RESTORE GAS SUPPLY FOR A LIST OF AUTHORIZED SERVICE AGENTS...

Page 10: ...TCH BURNERS ON OFF LEFT SIDE BURNERS ON OFF RIGHT SIDE BURNERS ON OFF MAIN POWER ON OFF BURNERS ON OFF MAIN POWER ON OFF RIGHT SIDE BURNERS ON OFF LEFT SIDE BURNERS ON OFF USE AND CARE Continued 7 To...

Page 11: ...grease tray are possible with this type of appliance and excessive amounts of grease in the tray can lead to a sustained flare up or fire which can be dangerous and result in personal and or property...

Page 12: ...s to stick even more When cleaning cast iron components such as the cooking grates radiants and burners do not handle these components roughly Dropping them on the floor or in the sink may cause them...

Page 13: ...ess steel Never spray or pour water on the unit to clean Always disconnect electrical power before cleaning accessible panels Weekly Periodic Cleaning In addition to the daily cleaning tasks outlined...

Page 14: ...e agency All repairs must be performed by a qualified technician using genuine Garland replacement parts or risk negating the warranty For a list of Authorized Service Agents to view a Genuine Parts l...

Page 15: ...Part 4530868 04 25 12 Page 15...

Page 16: ......

Page 17: ...Pi ce n 4530868 04 25 12 Page 16...

Page 18: ...Pi ce n 4530868 04 25 12 Page 15...

Page 19: ...es performances et pour effectuer les r glages n cessaires De plus un nettoyage derri re les panneaux non accessibles comme le panneau avant et ou les panneaux des pieds doit galement tre effectu lors...

Page 20: ...nneuse chaude 3 3 Gratter la goutti re graisse et la rigole en dirigeant la graisse et les d bris dans le s tiroir s graisse Vider le s tiroir s graisse en grattant la graisse les d bris attach s Lave...

Page 21: ...ge des composants en fonte comme les grilles de cuisson les radiants et les br leurs ne pas manipuler ces composants avec brutalit Le fait de les laisser tomber sur le sol ou dans l vier peut causer d...

Page 22: ...tre maintenu contre le plateau de fa on ne pas obstruer la circulation de l air vers et autour de l unit en particulier entre le plateau graisse et le panneau des robinets Il est important que les pl...

Page 23: ...d Ed Ed ZZhWd WZ E W D Z ZZ d Zk hZ h hD d Ed Zk hZ hD d Ed Zk hZ hD d Ed Zk hZ ZK d hD d Ed Zk hZ ZK d hD d Ed Ed ZZhWd WZ E W D Z ZZ d UTILISATION ET ENTRETIEN suite 7 Pour arr ter l unit il suffit...

Page 24: ...ourner l obturateur pour laisser PLUS d air entrer dans la cavit du br leur Si les flammes semblent se d tacher des orifices du br leur tourner l obturateur pour laisser MOINS d air entrer dans la cav...

Page 25: ...ON DE LA CONDUITE D ALIMENTATION D PASSE CETTE VALEUR MAXIMALE UN R GULATEUR R DUCTEUR SERA N CESSAIRE ET DEVRA TRE INSTALL CONFORM MENT AUX CODES LOCAUX LE BOUCHON DE VENTILATION FAIT PARTIE DU R GUL...

Page 26: ...fi en cas de doute sur la prise de courant NE PAS UTILISER DE RALLONGE POUR CONNECTER CETTE UNIT UNE PRISE DE COURANT NE PAS UTILISER CET APPAREIL SI LE CORDON D ALIMENTATION EST ENDOMMAG NE PAS ESSAY...

Page 27: ...cis La plaque signal tique contient d autres informations importantes essentielles pour l installation correcte de l unit Elle sp cifie le type et la pression du gaz la tension et les exigences de d g...

Page 28: ...net de r glage manuel Cordon d alimentation de 9 pieds avec prise NEMA 5 15P pour les mod les 120 V standard Outil avec brosse m tallique et grattoir combin s inclus pour le nettoyage des grilles R gu...

Page 29: ...52 000 280 127 29 9 0 846 HEEGM36CL 45 1143 45 1143 25 1 2 648 6 87 000 78 000 420 191 29 9 0 846 HEEGM48CL 65 1651 45 1143 25 1 2 648 9 130 500 117 000 560 254 43 2 1 223 HEEGM60CL 65 1651 45 1143 2...

Page 30: ...nement et installation 6 Socle en option 7 Alimentation en air et ventilation 7 Raccordement lectrique 7 Connexion du gaz 8 D marrage 8 UTILISATION ET ENTRETIEN 9 Fonctionnement 9 Avertissements 11 qu...

Page 31: ...res de laine de verre fibres c ramiques L inhalation de ces particules de laine de verre ou de fibres c ramiques est reconnue par l tat de Californie comme causant le cancer L utilisation de ce produ...

Page 32: ...ces et service U 1 800 424 2411 Ventes Canada 1 888 442 7526 Pi ces Service Canada ou U 1 800 427 6668 Pi ce n 4530868 04 25 12 2012 Garland Commercial Ranges Ltd POUR VOTRE S CURIT NE PAS STOCKER NI...

Reviews: