background image

Part # 4530868 (04/25/12)

Page 10

4.  Once the desired power switch(es) have been turned to 

the “ON” position, the burners should ignite quickly.  If 

sparking continues and/or a burner does not light, shut 

down power to the unit by turning the switch(es) to 

the “OFF” position and wait 5 minutes before repeating 

ignition.  If ignition fails repeatedly, shut down power to 

the unit and contact a qualified service technician.

5.  It is recommended that the unit run for approximately 30 

minutes on start up to reach the desired temperature.

6.  For temperature adjustment, each burner has a control 

knob which will adjust the height of the flame from a high 

to a low position.  

120V SINGLE SWITCH   

  

120V DOUBLE SWITCH

220-240V SINGLE SWITCH

220-240V DOUBLE SWITCH

$

BURNERS

ON/OFF

LEFT SIDE
BURNERS

ON/OFF

RIGHT SIDE

BURNERS

ON/OFF

MAIN

POWER

ON/OFF

BURNERS

ON/OFF

MAIN

POWER

ON/OFF

RIGHT SIDE 

BURNERS

ON/OFF

LEFT SIDE
BURNERS

ON/OFF

USE AND CARE Continued

7.  To shut off the unit, the operator simply needs to turn off 

the power switch(es).  When shutting down for longer 

periods of time, it is best to also close the manual shut-off 

valve to the unit.

8.  The cooking grates can be installed in 2 positions, to 

provide flexibility when preparing different types of food.  

To install the cooking grates in the standard position, 

the rear feet on the grates should be placed through the 

square cutouts on the rear wall of the broiler.  To install the 

cooking grates in the elevated position, the groove in the 

feet of the grates should be placed on the top edge of the 

rear wall of the broiler.  Grates must be manually moved 

from one position to another; and therefore, should be 

moved when the grates are cool.

Summary of Contents for HEEGM XX CL

Page 1: ...0 USA Sales Parts and Service 1 800 424 2411 Canadian Sales 1 888 442 7526 Canada or USA Parts Service 1 800 427 6668 Part 4530868 04 25 12 2012 Garland Commercial Ranges Ltd FOR YOUR SAFETY DO NOT ST...

Page 2: ...uld expose you to airborne particles of glass wool ceramic fibers Inhalation of airborne particles of glass wool ceramic fibers is known to the state of California to cause cancer Operation of this pr...

Page 3: ...STALLATION 6 General 6 Positioning and Setup 6 Optional Stand 7 Air Supply and Ventilation 7 Electrical Connection 7 Gas Connection 8 Start Up 8 USE AND CARE 9 Operation 9 Warnings 11 Optional Equipme...

Page 4: ...EGM36CL 45 1143 45 1143 25 1 2 648 6 87 000 78 000 420 191 29 9 0 846 HEEGM48CL 65 1651 45 1143 25 1 2 648 9 130 500 117 000 254 560 43 2 1 223 HEEGM60CL 65 1651 45 1143 25 1 2 648 11 159 500 143 000...

Page 5: ...vidually controlled by a manual high low valve 9 ft power cord with NEMA 5 15P plug for standard 120V models Wire brush and scraper combination tool included for cleaning grates gas regulator for appl...

Page 6: ...e rating plate contains other important information critical to the proper installation of the unit It specifies the gas type gas pressure voltage and clearance requirements for the appliance INSTALLA...

Page 7: ...T USE AN EXTENSION CORD TO CONNECT THIS UNIT TO A POWER SUPPLY DO NOT USE THIS APPLIANCE IF THE POWER CORD IS DAMAGED DO NOT ATTEMPT TO REPAIR A DAMAGED POWER CORD TAKE CARE NOT TO EXPOSE THE POWER CO...

Page 8: ...ING IS REQUIRED INSTALL IN ACCORDANCE WITH LOCAL CODES 3 A certified flexible gas hose and quick disconnect assembly with suitable strain relief is recommended for connection from the gas supply line...

Page 9: ...TURN THE POWER OFF AND CLOSE THE MANUAL SHUT OFF VALVE TO THE APPLIANCE CONTACT AN AUTHORIZED SERVICE AGENT FOR SERVICE BEFORE ATTEMPTING TO RESTORE GAS SUPPLY FOR A LIST OF AUTHORIZED SERVICE AGENTS...

Page 10: ...TCH BURNERS ON OFF LEFT SIDE BURNERS ON OFF RIGHT SIDE BURNERS ON OFF MAIN POWER ON OFF BURNERS ON OFF MAIN POWER ON OFF RIGHT SIDE BURNERS ON OFF LEFT SIDE BURNERS ON OFF USE AND CARE Continued 7 To...

Page 11: ...grease tray are possible with this type of appliance and excessive amounts of grease in the tray can lead to a sustained flare up or fire which can be dangerous and result in personal and or property...

Page 12: ...s to stick even more When cleaning cast iron components such as the cooking grates radiants and burners do not handle these components roughly Dropping them on the floor or in the sink may cause them...

Page 13: ...ess steel Never spray or pour water on the unit to clean Always disconnect electrical power before cleaning accessible panels Weekly Periodic Cleaning In addition to the daily cleaning tasks outlined...

Page 14: ...e agency All repairs must be performed by a qualified technician using genuine Garland replacement parts or risk negating the warranty For a list of Authorized Service Agents to view a Genuine Parts l...

Page 15: ...Part 4530868 04 25 12 Page 15...

Page 16: ......

Page 17: ...Pi ce n 4530868 04 25 12 Page 16...

Page 18: ...Pi ce n 4530868 04 25 12 Page 15...

Page 19: ...es performances et pour effectuer les r glages n cessaires De plus un nettoyage derri re les panneaux non accessibles comme le panneau avant et ou les panneaux des pieds doit galement tre effectu lors...

Page 20: ...nneuse chaude 3 3 Gratter la goutti re graisse et la rigole en dirigeant la graisse et les d bris dans le s tiroir s graisse Vider le s tiroir s graisse en grattant la graisse les d bris attach s Lave...

Page 21: ...ge des composants en fonte comme les grilles de cuisson les radiants et les br leurs ne pas manipuler ces composants avec brutalit Le fait de les laisser tomber sur le sol ou dans l vier peut causer d...

Page 22: ...tre maintenu contre le plateau de fa on ne pas obstruer la circulation de l air vers et autour de l unit en particulier entre le plateau graisse et le panneau des robinets Il est important que les pl...

Page 23: ...d Ed Ed ZZhWd WZ E W D Z ZZ d Zk hZ h hD d Ed Zk hZ hD d Ed Zk hZ hD d Ed Zk hZ ZK d hD d Ed Zk hZ ZK d hD d Ed Ed ZZhWd WZ E W D Z ZZ d UTILISATION ET ENTRETIEN suite 7 Pour arr ter l unit il suffit...

Page 24: ...ourner l obturateur pour laisser PLUS d air entrer dans la cavit du br leur Si les flammes semblent se d tacher des orifices du br leur tourner l obturateur pour laisser MOINS d air entrer dans la cav...

Page 25: ...ON DE LA CONDUITE D ALIMENTATION D PASSE CETTE VALEUR MAXIMALE UN R GULATEUR R DUCTEUR SERA N CESSAIRE ET DEVRA TRE INSTALL CONFORM MENT AUX CODES LOCAUX LE BOUCHON DE VENTILATION FAIT PARTIE DU R GUL...

Page 26: ...fi en cas de doute sur la prise de courant NE PAS UTILISER DE RALLONGE POUR CONNECTER CETTE UNIT UNE PRISE DE COURANT NE PAS UTILISER CET APPAREIL SI LE CORDON D ALIMENTATION EST ENDOMMAG NE PAS ESSAY...

Page 27: ...cis La plaque signal tique contient d autres informations importantes essentielles pour l installation correcte de l unit Elle sp cifie le type et la pression du gaz la tension et les exigences de d g...

Page 28: ...net de r glage manuel Cordon d alimentation de 9 pieds avec prise NEMA 5 15P pour les mod les 120 V standard Outil avec brosse m tallique et grattoir combin s inclus pour le nettoyage des grilles R gu...

Page 29: ...52 000 280 127 29 9 0 846 HEEGM36CL 45 1143 45 1143 25 1 2 648 6 87 000 78 000 420 191 29 9 0 846 HEEGM48CL 65 1651 45 1143 25 1 2 648 9 130 500 117 000 560 254 43 2 1 223 HEEGM60CL 65 1651 45 1143 2...

Page 30: ...nement et installation 6 Socle en option 7 Alimentation en air et ventilation 7 Raccordement lectrique 7 Connexion du gaz 8 D marrage 8 UTILISATION ET ENTRETIEN 9 Fonctionnement 9 Avertissements 11 qu...

Page 31: ...res de laine de verre fibres c ramiques L inhalation de ces particules de laine de verre ou de fibres c ramiques est reconnue par l tat de Californie comme causant le cancer L utilisation de ce produ...

Page 32: ...ces et service U 1 800 424 2411 Ventes Canada 1 888 442 7526 Pi ces Service Canada ou U 1 800 427 6668 Pi ce n 4530868 04 25 12 2012 Garland Commercial Ranges Ltd POUR VOTRE S CURIT NE PAS STOCKER NI...

Reviews: