6.7 hb_holdtime (hb_holdtime)
The IBS monitors the received packets on monitor port1, if heartbeat packets do not arrive
within “hb_holdtime” msec, the IBS will set the Active Bypass to Bypass/TAP/Linkdrop mode,
depending on active switch expire state.
To secure reliable detection of Application failure, the " hb_holdtime " value should be at
least 3 times the “hb_interval” parameter value. (default - 20, min - 10, max - 50000).
The " hb_holdtime " value is preserved after reset and power off events.
Example:
6.8 Keep heartbeat active mode (keep_hb_act_mode)
When “ keep_hb_act_mode” is ON the state of heartbeat active mode is preserved after
reboot or after power on events. When the keep_hb_act_mode is OFF the state of heartbeat
active mode is automatically set to ON after reboot or after power on.
Default value of the keep_hb_act_mode is OFF ( disabled).
Example: