EdgeSafe Bypass TAP (IBS) Installation
5.1 Rack mount the EdgeSafe IBS
The IBS is a rack mounting ready box. To rack mount the IBS:
1. Attach the 2 mounting flanges to the IBS using 3 screws for each mounting flange.
2. Slide the IBS into 1U slot and screw the IBS to the rack using 2 screws on each
mounting flange.
5.2 Connecting Power to the AC IBS unit (230V/120V)
5.2.1
Verify that the power switch on the IBS unit is OFF.
5.2.2
Connect two power cables to the power supplies on to the back of the IBS. The PWR led's on the
front panel of the IBS will illuminate when switching on the power switch power.
5.3 Connecting Power to the DC IBS unit (-48VDC)
5.3.1
Use DC power source -48V DC with circuit breaker 5A
5.3.2
Verify that the power is OFF on the DC power source
5.3.3
Verify that the power switch on the IBS unit is OFF
5.3.4
Connect the DC input wires to the DC input terminal on the IBS as follows:
i.
Connect wire to ground terminal IBS ( left)
ii.
Connect 0V return to "+" terminal IBS ( center)
iii.
Connect -48V wire to "-" terminal ( right) IBS
iv.
Turn on the DC power source The PWR led that is on the front
panel of the IBS will illuminate
Garland Technology | 716.242.8500 |