EdgeSafe 10G Modular Bypass | Firmware Rev Level: 0.3.3.2
When heartbeat active mode is ON and the IBS does not detect the heartbeat packet
received from the monitor port the IBS will switch to Active Bypass or TAP or Linkdrop mode
according to the predefined settings of the switch expire state.
When heartbeat active mode is set to OFF the IBS stops sending the heartbeats and the IBS
can be set manually via the management port to one of the following modes Normal (Inline),
Active Bypass, TAP or Linkdrop mode.
By default Heartbeat active mode is not preserved after reset or after power off cycle. The
Heartbeat active mode can be configured to be preserved after reset or power off cycle by
enabling the keep_hb_act_mode parameter.