USER GUIDE
EdgeSafe 10G Modular Bypass | Firmware Rev Level: 0.3.3.2
10.4.2 IBS10G-SR / IBS10G-SR
10.4.2.1 IBS1U/IBS1UP: Fiber Gigabit Ethernet Technical Specifications - (Base-SR) Adapters
IEEE Standard / Network topology:
Fiber Gigabit Ethernet, Base-SR (850nM)
Data Transfer Rate:
20Gbit/s in full duplex mode per port
Cables and Operating distance:
Multimode fiber: 62.5um 16.5m
maximum at 62.5 um **
Theoretical Distance – Defined as half a distance as stated by
the
IEEE 802.3 standard
Output Transmit Power:
Typical: -2.6 dBm
Minimum: -3 dBm
Optical Receive Sensitivity:
Typical: -14.6 dBm
Maximum: -11.1 dBm
Insertion Loss (Passive: Normal
Mode)
Typical: 0.8 dB
Maximum: 1.9 dB
Insertion Loss (Passive: Bypass Mode)
Typical: 0.8 dB
Maximum: 1.9 dB
Voltage:
12V
Power Consumption:
25W max.
Operating Humidity:
0%–90%, non-condensing
Operating Temperature:
0°C – 40°C (32°F - 104°F)
Storage Temperature:
-20°C–65°C (-4°F–149°F)
EMC Certifications:
Class B / FCC / CE / VCCI
Safety:
UL
MTBF*:
> 150,000 hours
10.4.2.2 LED and Connector Specifications
LEDs:
Network / Monitor ports:
Link LED – (Green) On Link partner is detected.
Activity LED – (Yellow) Blinks on activity.
Power - Green power is on
Normal – Green, Switch in Normal mode.
SysOK – Yellow when Sys is OK,
WDT – Blink Yellow when WDT is activated Light
Yellow WDT time out
Off: WDT is disabled
Bypass - Red when bypass, off on Normal
Alarm – Red on system alarm
Connectors:
Network: 2 LC Duplex
Monitor: 2 SFP+
Management: RJ-11 serial port, RJ-45 1G copper
Ethernet
Garland Technology | 716.242.8500 |