MAINTENANCE SCHEDULE (See Detail Notes above)
Maintenance Action
Every 8
Hours
Every
125
Hours
Every
150
Hours
Every
1000
Hours
Every
4000
Hours
Every
Year
Check/Change Air Filter ** .................................................
•
Change Oil Separator *** ..................................................
•
•
Check Reservoir Oil Level **** ...........................................
•
Check for Proper Load/Unload...........................................
•
Check Fault Indicator Lights...............................................
•
Check Dirt Accumulation on Cooler ...................................
•
Change Oil Filter Element & Clean Oil Return Strainer &
Orifices ...............................................................................
•
Change Compressor Lubricant (AEON 4000) * .................
•
Check Relief Valve.............................................................
•
Check Condition of Hoses..................................................
•
•
Check Operation of Condensate Removal Solenoid Valve
•
Change Inlet Valve Seals...................................................
•
* See “Oil Change Interval Chart”, Figure 5-3, page 47, for specific lubricant life.
** Check/change more often in dirty environments.
*** Also change when 8 psi
∆
P across the element.
**** Must be checked when the compressor is stopped and the air/oil mixture is separated.
Summary of Contents for INTEGRA EFA99F
Page 15: ...13 8 639 Page 15 Figure 2 2 OUTLINE UNIT PACKAGE 300EFA804 A Ref Drawing ...
Page 39: ...13 8 639 Page 39 WIRING DIAGRAMS 3 PHASE ...
Page 40: ...13 8 639 Page 40 WIRING DIAGRAMS 3 PHASE ...
Page 41: ...13 8 639 Page 41 WIRING DIAGRAMS 3 PHASE ...
Page 42: ...13 8 639 Page 42 WIRING DIAGRAMS 1 PHASE ...
Page 43: ...13 8 639 Page 43 WIRING DIAGRAM 1 PHASE ...