Use the scroll key ( ) to select the desired option for programming. The numerical values can be
changed with the up arrow or the down arrow keys. The value flashes on the display to indicate change.
When the flashing stops, the value becomes the new setting. The following can be programmed through
the MULTIPILOT MENU.
Compressor identification number:
The display shows alternately the text RS 485 and the compressor number.
When no indicator lights are on, the compressor identification number can be changed.
The number flashes quickly as its value is being changed.
Selecting the pressure control point:
The compressor’s pressure control point can be changed here. The text LOCAL indicates control by
the compressor, while the text PILOT means control by the MultiPilot system.
REMOTE CONTROL OPERATION
- Remote control operation is selected by turning the selector switch
on the cabinet clockwise, Figure 4-2, page 28, detail number 21.
In the remote control mode the compressor is operated with a closing contact which is connected to
terminal blocks 22 and 30 of the compressor control box. The compressor is started by closing the
contact and stopped by opening it.
Summary of Contents for INTEGRA EFA99F
Page 15: ...13 8 639 Page 15 Figure 2 2 OUTLINE UNIT PACKAGE 300EFA804 A Ref Drawing ...
Page 39: ...13 8 639 Page 39 WIRING DIAGRAMS 3 PHASE ...
Page 40: ...13 8 639 Page 40 WIRING DIAGRAMS 3 PHASE ...
Page 41: ...13 8 639 Page 41 WIRING DIAGRAMS 3 PHASE ...
Page 42: ...13 8 639 Page 42 WIRING DIAGRAMS 1 PHASE ...
Page 43: ...13 8 639 Page 43 WIRING DIAGRAM 1 PHASE ...