![background image](http://html1.mh-extra.com/html/gardner-denver/airsmart-g2/airsmart-g2_operating-and-service-manual_3568235066.webp)
13-25-606 Page 64
12-3
SYMPTOM
POSSIBLE CAUSE
REMEDY
Oil carryover
1.
Overfilling the reservoir.
1.
Drain excess oil from
system.
2.
Clogged scavenge orifice
2.
Inspect and cleanse.
3.
Ruptured oil separator
element.
3.
Replace element.
4.
Loose assembly.
4.
Tighten all fittings and
gaskets.
5.
Foaming caused by use of
incorrect oil.
5.
Use Gardner Denver
AEON lubricating coolant.
6.
Inoperative minimum
pressure valve.
6.
Inspect and/or replace.
7.
Operation at elevated
discharge temperatures.
7.
Reduce temperature. See
“High Discharge Air
Temperature
”, this
section.
8.
Water condensate in oil.
8.
Check oil reservoir
temperature and if low,
change thermal mixing
valve element to one with
higher temperature
setting.
Excessive water in air
delivery line
1.
Water separator drain
(basic unit or total system
receiver and/or dryer)
malfunction.
1.
Inspect and cleanse or
replace drain float valve
2.
Dryer not energized
2.
Check that dryer is
plugged in and turned on.
3.
Dryer bypass valve is in
bypass position
3.
Inspect and cleanse.
4.
Dryer malfunction
3.
Refer to dryer manual for
further details.
Air/oil under pressure will cause severe personal injury or death. Shut down
compressor, relieve system of all pressure, disconnect, lockout and tagout
power supply to the starter before removing valves, caps, plugs, fittings, bolts
and filters
Summary of Contents for AirSmart G2
Page 2: ......
Page 30: ...4 6 13 25 606 Page 28 300UCC546 C Ref Drawing Page 2 of 3...
Page 31: ...13 25 606 Page 29 4 7 300UCC546 C Ref Drawing Page 3 of 3...
Page 33: ...13 25 606 Page 31 4 9 303UCC546 D Ref Drawing Page 2 of 3...
Page 34: ...13 25 606 Page 32 4 10 303UCC546 D Ref Drawing Page 3 of 3...
Page 69: ...NOTES...
Page 70: ...NOTES...
Page 71: ...NOTES...