13-25-606 Page 20
3-3
11.
Target Pressure -
This is the package discharge pressure that the controller would maintain if inlet
modulation, by any means (e.g., variable speed or inlet throttling), was available. Inlet modulation is
not available with this fixed speed compressor package, thus the target pressure value does not
initiate any action. To avoid conflicts, set this value approximately half-way between the Load and
Unload settings.
Operation at excessive discharge air pressure can cause personal injury or
damage to equipment. Do not adjust the full discharge air pressure above the
maximum stamped on the unit nameplate.
12.
Operating Mode
- See "Operational Settings, Operating Mode" menu in Controller Operating and
Service Manual.
13.
Enclosure
- Check for damaged panels or doors. Check all screws and latches for tightness. Be
sure doors are closed and latched.
The compressor starts and stops automatically. Automatic restarting can
cause injury or death. Open, lockout and tag out main disconnect and any
other circuits before servicing the unit.
The enclosure doors must be closed and latched to keep the compressor
package from overheating when the compressor is running.
After an emergency stop, be sure that the pressure in the air/oil reservoir is less
than 5 psig. Wait one minute or more before restarting.
Summary of Contents for AirSmart G2
Page 2: ......
Page 30: ...4 6 13 25 606 Page 28 300UCC546 C Ref Drawing Page 2 of 3...
Page 31: ...13 25 606 Page 29 4 7 300UCC546 C Ref Drawing Page 3 of 3...
Page 33: ...13 25 606 Page 31 4 9 303UCC546 D Ref Drawing Page 2 of 3...
Page 34: ...13 25 606 Page 32 4 10 303UCC546 D Ref Drawing Page 3 of 3...
Page 69: ...NOTES...
Page 70: ...NOTES...
Page 71: ...NOTES...