13-25-606 Page 22
3-5
Quick Start Guide
For your convenience, the following excerpt from the Controller Operating and Service Manual is
presented to assist in programming the basic operating parameters. However, we strongly recommend
you read the Controller Operating and Service manual before attempting operating the compressor
package.
·
Controller Hardware layout.
o
See Fig 3-1 for the layout of the main screen and input devices.
o
The functions available (e.g., "enter", "left arrow", "select", etc) on any menu are shown on
lower and right edge of the screen, next to seven (7) adjacent keypad buttons. To select a
function, the adjacent keypad button must be pressed!
o
The "STOP" and "RUN" keypad buttons are separate and self evident in Figure 3-1.
·
Setting the Target, Unload, and Load Pressures
1.
Press "menu" button
2.
Navigate with [
↑↓
] button to "Operation" sub-menu and press [
8
] button to enter selection.
3.
Navigate with [
↑↓
] button to "Set Points" sub-menu and press [
8
] button to enter selection.
4.
Navigate with [
↑↓
] button to "Target Pressure" sub-menu and press [
8
] button to enter
selection - see Fig 3-2 for value entry display.
5.
Last stored target pressure value is displayed on top are and cursor is located at "clr" (clear)
command key. Press "sel" button to clear displayed target pressure. Note that cursor location
is evident by font color change (yellow) of numeral displayed.
6.
Navigate with [
↑↓
] button to first numeral key and press [
8
] button to enter selection.
7.
Navigate with [
↑↓
] button to second numeral key and press [
8
] button to enter selection.
8.
Navigate with [
↑↓
] button to third numeral key and press [
8
] button to enter selection.
9.
Navigate with [
↑↓
] button to "Enter" key and press [
8
] button to enter selection. The target
pressure value is stored in the Controller.
10.
Navigate with [
↑↓
] button to "Back" key and press [
8
] button to return to the previous (Set
Points) sub-menu.
11.
Repeat steps 2 to 10 to select and set the "Unload" and "Load" pressure values.
Figure 3- 1 – Controller Layout and Main Screen
Figure 3- 2 – Typical Value Entry Screen
Summary of Contents for AirSmart G2
Page 2: ......
Page 30: ...4 6 13 25 606 Page 28 300UCC546 C Ref Drawing Page 2 of 3...
Page 31: ...13 25 606 Page 29 4 7 300UCC546 C Ref Drawing Page 3 of 3...
Page 33: ...13 25 606 Page 31 4 9 303UCC546 D Ref Drawing Page 2 of 3...
Page 34: ...13 25 606 Page 32 4 10 303UCC546 D Ref Drawing Page 3 of 3...
Page 69: ...NOTES...
Page 70: ...NOTES...
Page 71: ...NOTES...