![background image](http://html1.mh-extra.com/html/gardner-denver/airsmart-g2/airsmart-g2_operating-and-service-manual_3568235062.webp)
13-25-606 Page 60
11-1
SECTION 11
MAINTENANCE SCHEDULE
SERVICE CHECK LIST
–
Air Filter and Pre-Filter
- Operating conditions determine frequency of service. See
“Air Filter,” Section
7, page 47.
Motor Lubrication
- Refer to Section 2, page 12
Every 8 Hours Operation
1.
Check the reservoir oil level - add oil if required. See Section 5, page 36.
2.
Observe if the unit loads and unloads properly.
3.
Check discharge pressure and temperature.
4.
Check control panel display for advisory text messages.
Every 125 Hours Operation
1.
Check for dirt accumulation on oil and air core finned faces and the cooling fan. If cleaning is
required, clean the exterior fin surfaces of the cores by blowing compressed air carrying a
nonflammable safety solvent in a direction opposite that of the cooling fan air flow. This cleaning
operation will keep the exterior cooling surfaces clean and ensure effective heat dissipation.
Every 1000 Hours Operation
1.
Change oil filter element.
Every 4000 Hours Operation
1.
Change the compressor lubricant. Under adverse conditions,
change more frequently
(refer to
“Oil
Change Interval
”, Figure 5-4, page 41. Flush system if required.
Every Year
1.
Check the pressure relief valve for proper operation.
See Section 9, page 52
.
2.
Change oil separator, see
“Removal of Oil Separator for Inspection or Replacement”, Section 5,
page 36 for further details (or when 8 psid pressure differential across the element).
Summary of Contents for AirSmart G2
Page 2: ......
Page 30: ...4 6 13 25 606 Page 28 300UCC546 C Ref Drawing Page 2 of 3...
Page 31: ...13 25 606 Page 29 4 7 300UCC546 C Ref Drawing Page 3 of 3...
Page 33: ...13 25 606 Page 31 4 9 303UCC546 D Ref Drawing Page 2 of 3...
Page 34: ...13 25 606 Page 32 4 10 303UCC546 D Ref Drawing Page 3 of 3...
Page 69: ...NOTES...
Page 70: ...NOTES...
Page 71: ...NOTES...