![background image](http://html1.mh-extra.com/html/gardner-denver/airsmart-g2/airsmart-g2_operating-and-service-manual_3568235063.webp)
13-25-606 Page 61
11-2
MAINTENANCE SCHEDULE (See Detail Notes above)
Maintenance Action
As Indicated by
AirSmart G2
Controller
Every
8
Hours
Every
50
Hours
Every
125
Hours
Every
1000
Hours
Every
4000
Hours
Every
Year
Check/Change Air Filter ..............................................
·
Check/Change Package Inlet Filters ............................
·
Change Oil Separator ................................................
·
·
Check Reservoir Oil Level
**
.......................................
·
Check for Proper Load/Unload ....................................
·
Check Dirt Accumulation on Cooler .............................
·
Change Oil Filter Element & Clean Oil Return Orifice ...
·
Change Compressor Lubricant (AEON 4000)
*
............
·
Check Relief Valve .....................................................
·
Check Condition of Hoses ...........................................
·
·
Check Operation of Condensate Removal Drain Valve
·
*
See
“Oil Change Interval Chart”, Figure 5-4 page 41, for specific lubricant life.
**