6 Troubleshooting
6.1
Error messages and fault rectification
Error message
Possible cause
Fault rectification
E1
Power fault
Power monitoring at the coil or the
power amplifier diagnosed.
Excessive / insufficient power.
Try again.
E2
Power amplifier in
operation
Generator programme in operation. Wait a short while before restarting.
E3
Cooler overtempera-
ture
Generator cooler is too hot (too
many heating cycles in too short a
time).
Allow the cooler to cool down.
E4
Initial temperature of
the cooler too high
Generator cooler is too hot (too
many heating cycles in too short a
time).
Wait a short while before restarting.
E5
Safety circuit open
Coil temperature > 60 °C (too many
heating cycles in too short a time).
Allow the coil to cool down, check
the cause.
E6
Invalid data
The generator has received invalid
data from the control panel.
Contact the manufacturer.
E7
Relay fault
Problems have arisen with the
power relay in the generator.
Contact the manufacturer.
E8
Fan fault
Problems have arisen with the fan
in the generator.
Contact the manufacturer.
E9
DIP switch invalid
Incorrect switch settings in the
generator.
Contact the manufacturer.
EA
Power amplifier
already in operation
An attempt has been made to start
the generator, although it is already
in operation.
X
Switch the unit off.
X
Switch the unit on again.
X
Try again.
Eb
Invalid hardware
Hardware problems in the genera-
tor.
Contact the manufacturer.
EC
Mains voltage too
high
An excessively high mains voltage
was detected.
Check the main voltages.
Ed
No load
The heating cycle was started when
no chuck was in the coil.
Try again.
EE
No coil present
Breakage in the cable or terminal
disconnected.
Contact the manufacturer.
EF
Telegram error
Communication to the generator
has been lost.
Contact the manufacturer.
dd
Initialisation error
When initialising the control panel
the unit found that it was switched
off or detected a fault.
Contact the manufacturer.
The initialisation of the control
panel must be repeated!
F1
F2
F3
F4
F5
F6
F8
Telegram error
Errors occurred in telegrams to and
from the generator.
Contact the manufacturer.
X
If because of these errors the SG1 cannot be commissioned, please contact the company that supplied
it or customer service department.
Summary of Contents for SG1
Page 2: ...A B C D E...
Page 190: ...188 DE EN FR IT ES CZ PL RU ZH ZH DE EN FR IT ES CZ PL 1 6 X X X X X Hoffmann Group...
Page 194: ...192 DE EN FR IT ES CZ PL RU ZH ZH DE EN FR IT ES CZ PL 3 3 1 230 400 230 400 230...
Page 198: ...196 DE EN FR IT ES CZ PL RU ZH ZH DE EN FR IT ES CZ PL 6 X X X X X...
Page 216: ...214 DE EN FR IT ES CZ PL RU ZH DE EN FR IT ES CZ PL RU 1 6 X X X X X...
Page 224: ...222 DE EN FR IT ES CZ PL RU ZH DE EN FR IT ES CZ PL RU 6 X X X X X...
Page 236: ...234 DE EN FR IT ES CZ PL RU ZH DE EN FR IT ES CZ PL RU 7 6 35 4200 SG1 35 4200 SG1 35 4200 SG1...
Page 239: ...03747 de Copyright Hoffmann Group www hoffmann group com GARANT Schrumpfger t SG1...