![GARANT SG1 Operation Manual Download Page 30](http://html1.mh-extra.com/html/garant/sg1/sg1_operation-manual_3454421030.webp)
28
DE
EN
FR
IT
ES
CZ
PL
RU
ZH
FR
IT
ES
CZ
PL
RU
ZH
DE
Control Panel
Automatic selection of shrink fitting parameters
Start or cancel / end the shrink fitting process, release the coil lock
Mode button: Chuck type and shank ⌀ selection, switching between operating modes
Boost button: Shrink fitting time increased by 15 %
Spray cooler: Switch on the optional SKE 1 spray cooling unit
Display chuck type:
SL = slim shrink-fit chuck
N = standard shrink-fit chuck
V = reinforced shrink-fit chuck
SC-green
= Shrink Collet shrink-fit chuck– Shrinking in
SC-red
= Shrink Collet shrink-fit chuck– Removing
MAN = manual performance selection
Increasing the diameter of the tool (only in automatic operating mode).
Increasing the power (only in manual operating mode)
Reducing the diameter of the tool (only in automatic operating mode).
Reducing the power (only in manual operating mode)
LED display
Each operating mode is indicated by the respective LED:
Automatic operating mode:
When the unit is not in an active cycle, the selected tool diameter is displayed in mm.
At the start of the shrink fitting process the display switches to the time remaining of the
generator in seconds.
Manual operating mode (hand symbol):
The display always shows the elapsed shrink time.
Fault condition:
In a fault condition an error number is displayed.
Display of the software version of the control panel
The uppermost mode LED (TV = yellow) lights up and software version of the control panel is
displayed for 5 seconds. Here the software version of the generator is displayed immediately.
Display of the software version of the generator
The third mode LED (TSF = yellow) lights up and software version of the generator is displayed for
5 seconds.
A contact
cooling
Positively driven contact
Contour-dependent cooling using the cooling inserts,
to avoid damage to the tool cutting edge
B
High-power coil
Hand-held coil with weight compensation
Maximum shrinkable tool length = 400 mm
C
Cooling inserts
Storage for cooling adapter
D
Screening plates
Different screening plates for ⌀ 3–32 mm
Optional screening plates for shrink collet chuck
E
Basic tool mounting
Taper reduction available for all shanks
Summary of Contents for SG1
Page 2: ...A B C D E...
Page 190: ...188 DE EN FR IT ES CZ PL RU ZH ZH DE EN FR IT ES CZ PL 1 6 X X X X X Hoffmann Group...
Page 194: ...192 DE EN FR IT ES CZ PL RU ZH ZH DE EN FR IT ES CZ PL 3 3 1 230 400 230 400 230...
Page 198: ...196 DE EN FR IT ES CZ PL RU ZH ZH DE EN FR IT ES CZ PL 6 X X X X X...
Page 216: ...214 DE EN FR IT ES CZ PL RU ZH DE EN FR IT ES CZ PL RU 1 6 X X X X X...
Page 224: ...222 DE EN FR IT ES CZ PL RU ZH DE EN FR IT ES CZ PL RU 6 X X X X X...
Page 236: ...234 DE EN FR IT ES CZ PL RU ZH DE EN FR IT ES CZ PL RU 7 6 35 4200 SG1 35 4200 SG1 35 4200 SG1...
Page 239: ...03747 de Copyright Hoffmann Group www hoffmann group com GARANT Schrumpfger t SG1...