de
en
cs
da
es
fr
hr
hu
it
nl
pl
ro
sl
8.2.
CONTROL CENTRE
Emergency Stop
Settings
Motor Fault
Level Switch
Pump Fault
2
1
1 Components functioning
normally
2 Component fault (red dis-
play)
8.3.
COMPOUND SELECTION
Settings
New Compound
UNI
SHINY
ALUMINIUM
PLASTIC
COPPER
1
2
3
4
1 Select pre-installed com-
pounds
3 Delete selected com-
pound
2 Edit compound
4 Add compound
9.
Cleaning
9.1.
WATER TANK
Protective gloves and safety glasses
CAUTION
Chemicals
Acid burns and heat burns of the skin, eyes, hands or feet.
» Wear safety glasses and protective gloves.
» Dispose of the compounds in accordance with the local regula-
tions.
» Comply with the safety data sheet from the respective com-
pound.
1. Open both the doors for access to the water tank.
2. Pull out the water tank.
3. Place the container under the outlet valves and open the out-
let valves.
4. Clean the water tank and dispose of the chemicals in accord-
ance with the national and regional regulations.
5. Alternatively use the wet and dry vacuum cleaner (Article no.
078541 751-11) to suck the contents from the entire water
tank.
6. Take out the filter, wash it and reinstall it.
7. Push the water tank into the surface finishing machine and
lock the doors.
10. Maintenance
It is mandatory to comply with the maintenance intervals.
DANGER
Electrically live components
Risk of fatal electric shock.
» Before starting any maintenance work switch the unit off and
disconnect it from the power supply, release it and protect it
from being switched on again.
» Check that the system is electrically dead, earth it and short cir-
cuit it.
» Insulate any adjacent electrically live components.
» Maintenance and repair may be performed only by electrical
specialists.
» If any live components suffer damage, have them repaired im-
mediately.
Interval
Maintenance work
Performed by
Every 20 operating hours
Clean abrasive chips and particles from the
water drain inserts in the trough.
Trained specialist for mechanical work
Each time the water is changed
Clean the stainless steel filter (stainless
steel filter in the water tank).
Check the water tank and float for correct
operation and clean them.
Trained person
Monthly or when very dirty
Trained person
3x a month
Visual inspection of the electric wiring.
Trained specialist for electro-technical work
Every 3 months
Clean the pump and all parts of the pump.
Trained specialist for mechanical work
Every 6 months
Replace the pump suction and discharge
hoses.
Motor unit
: Check the motor, covers, seals
and screw fastenings.
Trained specialist for mechanical work
Annually
Check the electrical equipment.
Safety check at the installation location.
Trained specialist for electro-technical work
Trough:
Check the trough, PU coating, frame,
steel springs and sieve.
Trained specialist for mechanical work
Regularly
Water pump:
Grease the contact face
between the rollers and water hose.
Trained specialist for mechanical work
10.1.
GREASE THE MOTOR
Under normal conditions no additional greasing of the motor is
necessary.
10.2.
EXCHANGING THE HOLD-DOWN CLAMPS
I
ü
If the hold-down clamps are no longer holding down the cover
on the trough.
1. Loosen the upper cap nut from the hold-down clamp.
» Take off the hold-down clamp together with the plastic
cover.
31
Summary of Contents for GMT35
Page 2: ...A B 1 2 3 4 2...
Page 3: ...C www hoffmann group com 3...
Page 4: ...D 1 2 3 4 5 7 8 6 4...
Page 5: ...1 2 3 E www hoffmann group com 5...
Page 6: ...1 2 3 4 5 F 6 6...
Page 7: ...1 2 3 4 5 6 G www hoffmann group com 7...
Page 8: ...1 2 3 H 4 8...
Page 9: ...i 2x I 1 2 www hoffmann group com 9...
Page 165: ...www hoffmann group com 165...
Page 166: ...166...
Page 167: ...www hoffmann group com 167...