Figure 73 shows the internal layout of the UV lamp enclosure. Refer to this picture
while performing the next steps of this procedure.
Figure 73: UV Lamp Enclosure Internal Layout
6. Remove the two plastic hole plugs from the top of the UV Lamp Enclosure to gain
access to the lamp retaining screws. The location of these two hole plugs is indicated
in Figure 75 by the red circle (#1).
7. Disconnect the three (3) lamp connection wires from the terminal strip, circled in yellow
in Figure 75 (#2).
8. Remove the two lamp retaining screws (5-40 x 3/8") from the lamp retaining ring using
a 3/32" ball driver passed through the removed hole plugs. The location of the front
retraining screw is marked by the blue circle (#3) in Figure 75.
9. Remove the lamp.
10. Place the new lamp in the lamp retainer on the lamp mount assembly. Ensure the lamp
is facing the correct direction. Refer to Figure 74 for the correct UV source lamp
orientation.