High Power Opto-Isolated Outputs
The DMC-40x0 has different interconnect module options, this section will describe the 500mA optically isolated
outputs that are used on the ICM-42x00.
Electrical Specifications
Output Common Max Voltage
30 VDC
Output Common Min Voltage
12 VDC
Max Drive Current per Output
0.5 A (not to exceed 3A for all 8 outputs)
Wiring the Opto-Isolated Outputs
The ICM-42x00 module allows for opto-isolation on all of the digital inputs and outputs. The digital outputs are
optically isolated and are capable of sourcing up to 0.5 A per pin with a 3 A limit for the group of 8 outputs. The
outputs are configured for hi-side drive only. The supply voltage must be connected to o
utput supply voltage
(OPWR), and the supply return must be connected to
output return
(ORET)
.
Figure 3-3 shows the manner in which the load should be connected. The output will be at the voltage that is
supplied to the OPWR pin. Up to 30 VDC may be supplied to OPWR.
Figure 3-3 ICM-42x00 General-Purpose Digital Output Opto-Isolation
4080
For controllers with 5-8 axes, outputs 9-16 are located on the I/O (E-H) D-Sub connector. The OPWR and
ORET for these outputs are also found on the I/O (E-H) D-Sub connector. Connections to the OPWR and
ORET on the I/O (E-H) as described above are required for operation of outputs 9-16.
DMC-40x0 User Manual
Chapter 3 Connecting Hardware
•
38
Summary of Contents for DMC-4040
Page 54: ...Chapter 3 Connecting Hardware 45 DMC 40x0 User Manual...
Page 55: ...DMC 40x0 User Manual Chapter 3 Connecting Hardware 46...
Page 56: ...Chapter 3 Connecting Hardware 47 DMC 40x0 User Manual...
Page 73: ...Figure 4 1 GalilTools DMC 40x0 User Manual Chapter 4 Software Tools and Communication 64...
Page 185: ...THIS PAGE LEFT BLANK INTENTIONALLY DMC 40x0 User Manual Chapter 7 Application Programming 176...
Page 205: ...THIS PAGE LEFT BLANK INTENTIONALLY DMC 40x0 User Manual Chapter 10 Theory of Operation 196...
Page 222: ...Step 2 Remove ICM s Appendices 213 DMC 40x0 User Manual...
Page 232: ...DMC 4080 Steps 4 and 5 Step 4 Replace ICM s Appendices 223 DMC 40x0 User Manual...