Jumper Description for CMB-41012
Jumper
Label
Function (If jumpered)
Communications
OPT
Reserved
MO
When controller is powered on or reset, Amplifier Enable
lines will be in a Motor Off state. A SH will be required to re-
enable the motors.
38.4K
Baud Rate setting – see
367H
table below
19.2K
Baud Rate setting – see
368H
table below
UPGD
Used to upgrade controller firmware when resident firmware
is corrupt.
MRST
Master Reset enable. Returns controller to factory default
settings and erases EEPROM. Requires power-on or RESET
to be activated.
Baud Rate Jumper Settings
19.2
38.4
BAUD RATE
ON
ON
9600
ON
OFF
19200
OFF
ON
38400
OFF
OFF
115200
A5 – CMB-41012 (-C012)
•
255
DMC-40x0 User Manual